Etap Library ❲ULTIMATE – 2024❳
If you are a senior engineer managing a team, protect the User Library with a password. This prevents junior engineers from accidentally changing the default impedance of a 50MVA transformer, which would invalidate the entire protection coordination study.
: The main project file structure that embeds localized library data. 2. Setting Paths and Access Control
Crucial for motor acceleration studies. It includes standard nameplate data, torque-speed curves, and current-speed curves, allowing engineers to simulate how a power system responds when massive industrial motors start up. Protective Device Library
Click the button to unlock modifications (requires administrative privileges within the project). Click Add to create a new manufacturer or model entry. etap library
The core function of the ETAP Library is to serve as an extensive, validated database of electrical equipment. It contains thousands of pre-modeled components, including synchronous generators, transformers, transmission lines, protective relays, circuit breakers, and variable frequency drives. However, what distinguishes this library from a generic parts list is its adherence to industry standards (e.g., IEC, ANSI, NEMA). Each component is not merely an icon; it is a mathematical model pre-loaded with characteristic curves—saturation curves for transformers, torque-speed curves for motors, and time-current curves for protective devices.
The library is segmented into distinct equipment types, each containing customized data sets relevant to their specific electrical properties and behaviors: 🛡️ Protective Devices (Star Module Coordination)
: Maintaining a versioned library system is recommended to track component changes and ensure project consistency. How to Add New Component Data If you are a senior engineer managing a
Navigate to Library > Library Editor . Here you can sort, filter, merge, and delete components. Sort by "Manufacturer" to see all ABB breakers. Filter by "Voltage Class" to isolate 15kV gear.
The ETAP library is a centralized database containing verified engineering data for electrical components. It includes technical specifications for thousands of devices from global manufacturers. Instead of manually entering data sheet values, engineers drop components into a one-line diagram and pull data directly from the library. The library houses parameters for several critical assets:
Marta copied pages, careful with the brittle tape. Following the notes, she imported a one-line model, assigned feeders, transformers, and motor loads, then ran an initial load-flow. Numbers appeared—bus voltages, real and reactive power—values that now had context. She adjusted transformer tap settings to bring the campus stub voltage into tolerance. The ETAP load flow offered suggestions she wouldn’t have found on her own: a lightly loaded feeder was causing an unexpected voltage rise; adding a shunt reactor at the substation tamed it. Protective Device Library Click the button to unlock
Next came short-circuit analysis. The notebook warned about incorrect substation grounding assumptions. Marta toggled the grounding model and re-ran the fault study. The relay time–current characteristic curves populated the background like a constellation. She plotted the inverse-time curves for the main feeder relay and the backup relay upstream, then nudged pickup currents and Time Multiplier Settings until the curves no longer intersected improperly. Each change updated a small checklist she kept on paper: coordination margin, breaker interrupting rating, SEL trip settings. A green checkmark beside “BF Relay > Upstream” felt oddly triumphant.
Select the specific models or manufacturers you wish to import.
(e.g., a low-voltage circuit breaker) on your single-line diagram. Double-click the component to open its Editor window. Navigate to the Rating or Trip tab. Click the Library button at the bottom of the window.