Hks-va028-v2.0 [repack]
It usually comes with two sets of wires—a thin set for power and a thick set for measuring the load current. Common Use Cases Bench Power Supplies:
Check for voltage drops in thin wiring; use thicker wires if measuring high-current loads. wiring diagram for a 12V automotive setup or a DIY power supply?
Before using the "hks-va028-v2.0," please read and follow these safety precautions:
Could you clarify if this is for a , industrial controller , or an automotive part ? hks-va028-v2.0
The VA028 creates a map using nodes. You define points (e.g., 1000 RPM, 3000 RPM, 6000 RPM).
The meter typically features two wiring harnesses (5 wires total) daroghawala.org Power Supply (Thin Wires) These wires power the LED display and internal circuitry. Positive terminal of the power source (DC 4.5–30V) AliExpress Thin Black: Negative terminal of the power source (Common Ground) AliExpress Measurement (Thick Wires) These wires handle the load being measured. Thick Red: Connected to the negative terminal of the load. Thick Black:
Check if the power supply (thin red/black) is within the 4.5–30V range and has correct polarity AliExpress 0.00 Current Reading: It usually comes with two sets of wires—a
Based on its classification alongside similar modules like the DSN-VC288 , the typical operating parameters include: : 0–100V DC.
Remove the blanking plate from your turbo manifold’s wastegate port. Clean gasket surfaces with a razor. Do not reuse old gaskets – HKS supplies a metal embossed gasket in the V2.0 box.
Before installation, identify the key components of the V2.0 unit: Before using the "hks-va028-v2
0.1V for voltage, 0.01A for current.
Voltage Measurement (Connect to the positive side of the circuit being measured) Note: It is crucial to ensure the working voltage ( ) does not exceed 30V30 cap V , or the meter might burn out. Why Choose the HKS-VA028-V2.0 HKS-VA028-V2.0
Connects to the true negative terminal of the main load power source.
The HKS-VA028-V2.0 optimizes high-accuracy tracking in a small form factor. It processes real-time voltage and current lines via an onboard analog-to-digital converter, splitting the telemetry onto a stacked 0.28-inch LED display panel. Technical Parameter Specification Value DC 0.00V to 99.9V (up to 100V) Current Measurement Range DC 0.000A to 9.999A (10A max with internal shunt) Display Window Dual 0.28-inch 3-digit/4-digit LED panels Refresh Rate ~200 milliseconds per cycle Measurement Accuracy ±1% (+/- 2 digits) Operating Current < 20mA total load Panel Cutout Dimension 45mm x 26mm Total Framework Footprint 48mm x 29mm x 26mm Pinout and Wiring Harness Architecture