Sinotimer Svp916 Manual Version Pdf Full Upd Official
To configure the device, follow these steps based on general Sinotimer SVP series logic:
Press and hold the button for 3 seconds to unlock parameter mode.
Action : Set the countdown time before the device delivers power after boot or recovery. Save Settings
Press and hold the button for 3 seconds to enter configuration mode.
: Continue pressing SET until the display shows "END" . Press SET one last time to save all changes and return to the main display. Indicator Light Guide Green Light : Normal operation; power is being supplied. sinotimer svp916 manual version pdf full
Press and hold the "Set" key for ~3 seconds until the display flashes.
Electrical stability is the backbone of any modern home, but voltage spikes or dips can wreck sensitive appliances in seconds. The SINOTIMER SVP-916
If under-voltage action time is set higher than , the relay may fail to drive due to MCU power loss. Safety Note: The neutral (
Sinotimer SVP-916 is an intelligent, adjustable over-voltage, under-voltage, and over-current protector designed for single-phase 230V AC systems. You can download the full PDF version of the manual from or view the official documentation hosted on Key Specifications Rated Voltage: AC 230V, 50/60Hz. Max Current: Up to 63A (models available in 40A and 80A). Protection Types: Over-voltage, under-voltage, and over-current. To configure the device, follow these steps based
The manual begins with critical warnings: disconnecting power before wiring, correct voltage ratings (usually 110–240V AC), and load limits (resistive vs. inductive). Diagrams show terminal connections (L, N, load, and override switch). Without this section, users risk electrical damage or injury.
For the most accurate wiring and safety precautions, always refer to the full version PDF SINOTIMER SVP-916 Manual available through official distributors like SINOTIMER Official wiring diagram explanation for a residential distribution board installation?
Shows both current voltage and current measurement in real-time.
This document provides the full operational manual content, complete with technical specifications, wiring configurations, and programming steps. Technical Specifications : Continue pressing SET until the display shows "END"
If no buttons are pressed for 10 seconds, the device saves all changes and exits to the main screen. Code Setting Matrix Adjustable Range Default Factory Value Power-On Delay Time 1 second ~ 500 seconds 10 seconds A2 Over-Voltage Protection Action Value 221V ~ 300V (or OFF) A3 Over-Voltage Recovery Voltage 220V ~ 299V A4 Over-Voltage Protection Action Time 0.1 second ~ 10 seconds 0.1 second A5 Under-Voltage Protection Action Value 150V ~ 219V (or OFF) A6 Under-Voltage Recovery Voltage 151V ~ 220V A7 Under-Voltage Protection Action Time 0.1 second ~ 10 seconds 0.1 second A8 Over-Current Protection Action Value 1A ~ 63A (or OFF) A9 Over-Current Protection Action Time 0.1 second ~ 50 seconds A10 Fault Recovery Delay Time 1 second ~ 500 seconds 30 seconds A11 Reset Type Mode AU (Auto Reset) / HA (Manual Reset) Safety Guidelines & Troubleshooting
: Connect the load/appliances to the bottom terminals. Connect the load Phase line to terminal L (OUT) . Connect the load Neutral line to terminal N (OUT) . Note: Wrong connections will damage the device permanently. ⚙️ Programming and Parameter Settings
Over-current protection reduces the risk of wiring overheating.
Experienced electricians and home automation enthusiasts have shared several insights that are not explicitly stated in the manual but can extend the relay’s service life: